ICU 8'' Portable Medical Patient Monitor Vital Sign ECG NIBP RESP TEMP SPO2 PR

$194.83 (-40%)

351

  • Return shipping will be paid by: Seller
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Expiration Date: Brand New
  • Number of Channels: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
  • Heart Rate: 15-300BPM(Adult) 15-350BPM(Neonatal)
  • All returns accepted: Returns Accepted
  • SpO2:: Measuring Range:0 ~ 100 %
  • RESP: Adult 0 ~ 120 rpm,Neo/Ped 0 ~ 150 rpm
  • Country/Region of Manufacture: China
  • Condition: New
  • warranty: 2 years
  • Dispaly: 8 inch TFT color screen
  • Features: Portable Patient Monitor
  • MPN: Does Not Apply
  • Monitor Parameters: Blood Pressure - NIBP
  • Lead Mode: Lead Mode:5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
  • Temperature:: Measuring and Alarm Range:0 ~ 50 C
  • NIBP: Method:Oscillometric
  • Brand: Unbranded
  • Intended Use/Discipline: Cardiology
  • Restocking Fee: No
  • Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
  • Screen Dimensions: 8 inch
  • Model: Portable patient monitor
  • Item must be returned within: 30 Days
  • Technology: Digital
  • Suitable for: adult, pediatric and neonatal patient
  • Description:
    Portable Patient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP. It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. Large high-resolution display provides clear view of 5 waveforms and full monitoring parameters.
    Features:
    8 inch TFT color screen
    Exquisite design suitable to moving operation
    Various interfaces: standard screen, trend screen, oxyCRG screen, NIBP list screen, big front screen.
    Real-time S-T segment analysis, pace-maker detection.
    Built-in rechargeable lithium battery, convenient for patient  moving.
    Suitable for adult, pediatric and neonatal patient
    Standard Configuration:
    SpO2, PR, NIBP, ECG, RESP, TEMP
    Technical Parameters:
    ECG:
    Lead Mode:5 Leads (
    R, L, F, N, C or RA, LA, LL, RL,V)
    Lead selection:I, II, III, avR, avL, avF, V,
    Waveform:2 ch
    Gain:2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
    Heart Rate:15-300BPM(Adult) 15-350BPM(Neonatal)
    Accuracy:± 1% or ± 1bpm,which great
    Resolution:1 bpm
    ST measurement Range:-2.0-+2.0mV
    Sweep Speed:12.5 mm/s,25mm/s,50mm/s
    Alarm:Available
    Review:Available
    RESP:
    Method Impedance between R-F(RA-LL)
    Measuring Range:Adult
    0 ~ 120 rpm,Neo/Ped 0 ~ 150 rpm
    Resolution:1 rpm
    Accuracy:
    ±
    2 rpm
    NIBP:
    Method:Oscillometric
    Mode:Manual, Auto, STAT
    Measuring and alarm range
    Adult Mode
    SYS:40 ~ 270 mmHg
    DIA:10 ~ 215 mmHg
    MEAN:20 ~ 235 mmHg
    Pediatric Mode
    SYS:40 ~ 200 mmHg
    DIA:10 ~ 150 mmHg
    MEAN:20 ~ 165 mmHg
    Neonatal Mode
    SYS:40 ~ 135 mmHg
    DIA:10 ~ 100 mmHg
    MEAN:20 ~ 110 mmHg
    Resolution:1mmHg
    Accuracy:+-5mmHg
    SpO2:
    Measuring Range:0 ~ 100 %
    Alarm Range:0 ~ 100 %
    Resolution:1 %
    Accuracy:70% ~ 100%
    ±
    2 %
    Actualization interval:about 1 Sec.
    Alarm Delay:10 Sec.
    Pulse Rate :0~254bpm
    Resolution:1bpm
    Accuracy:
    ±
    2bpm
    Temperature:
    Measuring and Alarm Range:0 ~ 50 C
    Resolution:0.1C
    Accuracy:0.1C
    Actualization interval:about 1 Sec.
    Average Time Constant:< 10 Sec.
    Package List:
    Patient monitor
    Temperature probe
    ECG lead cable
    ECG electrode
    Adult NIBP cuff
    NIBP extension tube
    Adult fingertip SpO2 probe
    Power cord
    User Manual
    FDA Disclaimer:
    The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
    ARTG NO: 278908 ARTG Number: 278908
    Statement: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. (The seller name: Helen Zhang,City:Beijing State: Beijing Country: China Telephone number: 86-18730611603)
    This item has been cleaned and treated according to the manufacturer’s instructions.
    The Fingertip Pulse-Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 136606, and certified by FDA of United States (Premarket Submission Number (510K): K073454 Listing Number: D045684, K082641 Listing Number: D064765, K090671 Listing Number: D078664); and CE Approved, TUV of Europe (Cert.No. : G1 10 02 50972 013).
    Payment information:
    PayPal
    only.
    Please pay the money within 5 days after the auction ended.
    Shipping method:
    All items will be shipped  within 1 business days.
    For US Buyer About 2-7 business days!
    We are not Responsible for your Customs duty.
    Terms of sale
    Warranty:
    We guarantees new equipment for a period of
    24 months
    . Our company’s obligation under this warranty is repairing or replacement.
    Return Policy :
    If you receive a defective item which you want to return, please contact us within 30 days from the day you receive the item. All return items must be returned with its original packaging and accessories.
    Feedback:
    Contact us first before leaving a negative, we will find a solution to meet your requirement and enhance the satisfaction.
    About us
    Quality First, Service Excellent, Global Trust!
    We are the manufacturer and distributor of medical equipments for more than 10 years. If you are interested in the distribution work, please feel free to contact us.
    We will reply to you within 24 hours. Please kindly wait for us.
    Contact us
    During the duty time ,we can give you a quick respond. If we are out of work ,please kindly be patient and considerable to give us a little more time ,not just leave the neutral or negative feedback without communication ,thank you for your cooperation !

    Main Menu